Have Questions?  Need Expert Answers?  JOIN LUNCH N' LEARNS!

Activate User

Prev Next
Step Details
Introduced in Version 4.2.0
Last Modified in Version 7.1.2
Location Integration > Okta

The Activate User step activates an Okta user account synced to Decisions. 

Prerequisites 

This step requires the Okta module to be installed before it will be available in the toolbox. 


Properties

Inputs

Property Description Data Type
User The Okta user account to activated. Set to constant OktaUser

Outputs

Property Description Data Type
Updated User The activated Okta user account OktaUser


Common Errors

Exception invoking method ActivateUser on class

This error occurs if the Okta module is not properly set up. In Decisions go to Settings > Okta > Edit Okta Settings. Review the Okta Subdomain or URL and confirm that it is correct. 

In Okta review the SAML settings under Applications > Decisions > General.

Exception Message:

Name: Error running step Activate User 1[ActivateOktaUserStep] in flow [Okta Test]: User ID is missing: This step can only be used with users retrieved from Okta.                 Exception Message: Error running step Activate User 1[ActivateOktaUserStep] in flow [Okta Test]: User ID is missing: This step can only be used with users retrieved from Okta.                                  Input Values: -- No Data --                                  Exception Stack Trace: DecisionsFramework.Design.Flow.ErrorRunningFlowStep: Error running step Activate User 1[ActivateOktaUserStep] in flow [Okta Test]: User ID is missing: This step can only be used with users retrieved from Okta. 
 ---> System.ArgumentException: User ID is missing: This step can only be used with users retrieved from Okta. 
   at Decisions.Okta.OktaUserManagementMethods.VerifyUserHasId(OktaUser user) 
   at Decisions.Okta.ActivateOktaUserStep.Run(StepStartData data) 
   at DecisionsFramework.Design.Flow.FlowStep.RunStepInternal(String flowTrackingID, String stepTrackingID, KeyValuePairDataStructure[] stepRunDataValues, AbstractFlowTrackingData trackingData) 
   at DecisionsFramework.Design.Flow.FlowStep.Start(String flowTrackingID, String stepTrackingID, FlowStateData data, AbstractFlowTrackingData trackingData, RunningStepData currentStepData)   
   --- End of inner exception stack trace ---

Related Information

Installing and Configuring Okta Module